Real-time temperature monitoring

V5B.
Follow the
cold chain.

Temperature, light and location, from dispatch to delivery.

The Frigga V5B is a single-use logger for connected shipment monitoring. Review available readings through the cloud platform and app, receive configured alerts and download a PDF record of the journey.

Single-use4G/5G connectivityUp to 60 days*
Frigga V5B real-time temperature, light and location data logger supplied by RTDL
Frigga technology. Australian supply and support.
Cloud access includedNo ongoing subscription fees.
Records while offlineRetransmits when the signal returns.
Australian supportPractical help with selection and setup.
A practical starting point

Keep the essential
information in view.

For growers, packers, exporters and logistics teams who need temperature visibility during transit, alongside light readings and cellular location information.

01 / TEMPERATURE

See changes during the journey.

The internal sensor measures from −30°C to +70°C. Use configured temperature alerts to flag readings outside your chosen limits.

02 / LIGHT

Add context to the record.

Light measurements can help identify exposure around the logger. Review changes alongside temperature and shipment events.

03 / LOCATION

Follow the available route information.

Cellular base station positioning provides location information when supported networks are available. Review it alongside the shipment readings.

V5B uses cellular base station positioning, rather than GPS. Transmission and location updates depend on network availability and the operating environment.

Cloud + mobile app

Check the shipment.
Keep the record.

Use the Frigga platform to review available shipment information on desktop or mobile, with access included in your V-Series purchase.

  • View temperature, light and cellular location information.
  • Receive configured alerts through email, SMS or the app.
  • Discuss recording intervals and alert thresholds with RTDL.
  • Download PDF reports through the cloud or USB.

No ongoing subscription fees apply to the included cloud access.

Dashboard shown for illustration. Available views and features depend on the device, account and configuration.

Frigga cloud shipment monitoring dashboard
Technical details

V5B specifications.

Key specifications for the single-use V5B (5G-60) model. For a non-lithium battery option, compare V5B Safe.

Measurements
Temperature, light and location
Temperature sensor
Internal sensor; NIST traceable
Temperature range
−30°C to +70°C
Temperature accuracy
±0.5°C from −20°C to +40°C; ±1°C outside this range
Temperature resolution
0.1°C
Light measurement
0 to 52,000 lux
Location
LBS cellular base station positioning
Operating duration*
Up to 60 days at 60-minute reporting
Recording interval
10 minutes; configurable through the platform
Reporting intervals
10, 20, 30 or 60 minutes
Memory
Up to 28,800 readings
Protection rating
IP64
Use / shelf life
Single-use / 12 months
Dimensions / weight
103 × 61.3 × 33 mm / 140 g
Connectivity
Global LTE 4G/5G with 2G fallback
Reports
PDF through USB, cloud platform and app

*Choose reporting settings to suit the journey.

Up to 60 days is based on 60-minute reporting. More frequent reporting and operating conditions affect battery duration. The logger records and stores readings while offline, then retransmits when the signal returns.

Getting started

Set up for the shipment.

01 / DISCUSS

Tell us about the journey.

Share the goods, route, expected journey time and temperature limits you need to monitor.

02 / CONFIGURE

Confirm settings and placement.

Agree on recording, reporting and alert settings, then follow the supplied start and placement instructions.

03 / MONITOR

Follow and review.

Review available readings through the platform and app, then download the report for your shipment records.

Before you order

A few practical questions.

When would I choose V5B over a USB logger?

Choose V5B when you need available temperature readings and configured alerts during transit. A USB logger may suit when a temperature history downloaded at destination is sufficient.

Does V5B measure humidity or use an external probe?

This V5B model measures temperature, light and location. For humidity and handling measurements, compare V5C Pro. For internal and external probe temperature measurements, compare V5Y.

What happens when there is no network signal?

The logger continues recording and storing readings while offline. It retransmits stored data when the signal returns. Live alerts and location updates depend on available connectivity.

How is V5B different from V5B Safe?

This page covers the V5B (5G-60) model. V5B Safe uses a non-lithium battery and has different specifications. Discuss the route, transport requirements and configuration with RTDL before ordering.

Are there ongoing cloud subscription fees?

No ongoing subscription fees apply to the cloud access included with your V-Series logger purchase.

Australian advice + support

Is V5B right
for your shipment?

Tell Allan what you are moving and where it is going. We will help confirm the model, setup and quantity you need.

Speak with Allan Anderson

0419 369 944

loggers@realtimedataloggers.com.au

Real Time Data Loggers · Mildura, Victoria
Manage the Outcome. The Data Tells the Story.